PDF

FG16OFR16 0,6/1 kV

Power, control and signaling cables, with steel wire armour, fire retardant and low halogens emission.

  1. Conductor
  2. Insulation
  3. Inner sheath
  4. Armour
  5. Outer sheath

Cca-S3,d1,a3

APPLICATION: Suitable for energy transport and the transmission of signals and controls where a certain level of mechanical protection (rodents-termites) is required.In the most risky environments in the event of a fire, such as health facilities, entertainment venues and entertainment in general, gyms and sports centers. Hotels, guest houses, motels, villages, tourist residences - hotels. Schools of every order, grade and type. Exhibitors and / or retailers. Companies and offices with more than 300 people present; Libraries and archives, museums, galleries, exhibitions and exhibitions. Buildings intended for civil use, with a fire height of more than 24m. (Average Risk)

INSTALLATION: For fixed indoor and outdoor installation even in wet environments. They can be installed on wall and metal structures, on platforms, pipes, conduits and similar systems. Cable for direct and indirect burial.

FEATURESDESCRIPTIONSTANDARD
Conductors: annealed red copper cl.5 CEI EN 60228 (Tab. 9)
Insulation: LSZH compound, G16 quality CEI EN 50363
Cores colour: CEI UNEL 00722 - HD 308
Inner sheath: Thermoplastic compound CEI EN 50363
Armour: Steel wire with steel tape wrapped helically
Outer sheath: Thermoplastic compound, R16 quality CEI EN 50363
Outer sheath colour: Grey RAL 7035
Low halogens emission: (< 22%) CEI EN 50267-2-1/2 - IEC 60754-1/2
DC resistance: According to CEI EN 60228 (Tab. 9)
Current capacity: CEI UNEL 35024/1 - CEI UNEL 35026
Rated voltage Uo/U: 0,6/1 kV
Max. voltage: 1,2 kV
Testing voltage: 4 kV
Max working temperature:

90 °C

Short-circuit temperature: 250 °C
Min. installation temperature: 0 °C
Bending radius: Ø x 14
Max standard twisting (2x cable): ≥ 10 twists/meter
REGULATION (UE) 305/2011
System AVCP : 1+ EN 50575:2014 + A1:2016
Classification : Cca-S3,d1,a3 UNI EN 13501-6
Cca : Heat release and flame spread (FS ≤ 2m) EN 50399
s3 : Smoke production (not s1 or s2) EN 50399
d1 : No flaming droplets/particles persisting longer than 10 s EN 50399
a3 : Gas acidity (not a1 or a2) EN 50267-2-3
Flame propagation (H ≤ 425 mm) EN 60332-1-2
Printing: BERICA CAVI S.P.A. ITALY FG16OFR16 0,6/1 kV Cca-S3,d1,a3 CE Type- Year/Lot - 00000 m

TYPE
N° x mm2
MEDIUM Ø OUTER
mm
MEDIUM WEIGHT
kg/km
PRODUCT CODE
2x1,512,0285B20C02150
3G1,512,5311 B20C03150
4G1,513,4349B20C04150
5G1,514,3397B20C05150
7G1,515,2460 B20C07150
10G1,518,4598B20C10150
12G1,519,2678B20C12150
16G1,521,1818B20C16150
19G1,522,1902B20C19150
24G1,524,91093B20C24150
2x2,512,8329B20C02250
3G2,513,4369B20C03250
4G2,514,4420B20C04250
5G2,515,4476B20C05250
7G2,516,7579B20C07250
10G2,520,2772B20C10250
12G2,521,1856B20C12250
16G2,523,41049B20C16250
24G2,527,41405B20C24250
2x414,2407B20C02400
3G414,8407B20C02400
4G16,1542B20C04400
5G417,4616B20C05400
2x615,7497B20C02600
3G616,4497B20C02600
4G617,7664B20C04600
5G619,3783B20C05600
2x1017,8658B20C021000
3G1018,9772B20C031000
4G1020,7931B20C041000
5G1022,41087B20C051000
2x1620,6897B20C021600
3G1621,71052B20C031600
4G1623,81276B20C041600
2x2524,21225B20C022500
3G2525,61466B20C032500
4G2528,11774B20C042500
3x35+1x/G2532,11800B20C043500
3x50+1x/G255,22420B20C045000

Berica Cavi Spa reserves the right to edit all the information on the website without providing prior notice to customers and / or users