PDF

FG16OAR16 0,6/1 kV

Power, control and signaling cables, with steel braid armour, fire retardant and low halogens emission.

  1. Conductor
  2. Insulation
  3. Inner sheath
  4. Armour
  5. Outer sheath

Cca-S3,d1,a3

APPLICATION: Suitable for energy transport and the transmission of signals and controls where a certain level of mechanical protection (rodents-termites) is required.In the most risky environments in the event of a fire, such as health facilities, entertainment venues and entertainment in general, gyms and sports centers. Hotels, guest houses, motels, villages, tourist residences - hotels. Schools of every order, grade and type. Exhibitors and / or retailers. Companies and offices with more than 300 people present; Libraries and archives, museums, galleries, exhibitions and exhibitions. Buildings intended for civil use, with a fire height of more than 24m. (Average Risk)

INSTALLATION: For fixed indoor and outdoor installation even in wet environments. They can be installed on wall and metal structures, on platforms, pipes, conduits and similar systems. Cable for direct and indirect burial.

FEATURESDESCRIPTIONSTANDARD
Conductors: Annealed red copper cl.5 CEI EN 60228 (Tab. 9)
Insulation: LSZH compound, G16 quality CEI EN 50363
Cores colour: CEI UNEL 00722 - HD 308
Inner sheath: Thermoplastic compound CEI EN 50363
Armour: Steel braid
Outer sheath: Thermoplastic compound, R16 quality CEI EN 50363
Outer sheath colour: grey RAL 7035
Low halogens emission: (< 22%) CEI EN 50267-2-1/2 - IEC 60754-1/2
Current capacity: CEI UNEL 35024/1 - CEI UNEL 35026
Rated voltage Uo/U: 0,6/1 kV
Max voltage: 1,2 kV
Testing voltage: 4 kV
Max working temperature:

90 °C

Short-circuit temperature : 250 °C
Min. installation temperature: 0 °C
Bending radius: Ø x 14
Max standard twisting (2x cable): ≥ 10 twists/meter
REGULATION (UE) 305/2011
System AVCP : 1+ EN 50575:2014 + A1:2016
Classification : Cca-S3,d1,a3 UNI EN 13501-6
Cca : Heat release and flame spread(FS ≤ 2m) EN 50399
s3 : Smoke production (not s1 or s2) EN 50399
d1 : No flaming droplets/particles persisting longer than 10 s EN 50399
a3 : Gas acidity (not a1 or a2) EN 50267-2-3
Flame propagation (H ≤ 425 mm) EN 60332-1-2
Printing: BERICA CAVI S.P.A. ITALY FG16OAR16 0,6/1 kV Cca-S3,d1,a3 CE Type- Year/Lot - 00000 m

TYPE
N° x mm2
MEDIUM Ø OUTER
mm
MEDIUM WEIGHT
kg/km
PRODUCT CODE
2x1,510,9182B16C02150
3G1,511,4204B16C03150
4G1,512,1235B16C04150
5G1,513,2274B16C05150
7G1,514,1328B16C07150
10G1,517,2449B16C10150
12G1,518,0502B16C12150
16G1,520,0630B16C16150
19G1,521,2717B16C19150
24G1,523,8872B16C24150
2x2,511,8220B16C02250
3G2,512,3250B16C03250
4G2,513,3298B16C04250
5G2,514,4343B16C05250
7G2,515,7426B16C07250
10G2,519,1584B16C10250
12G2,520,1668B16C12250
16G2,522,3831B16C16250
24G2,526,51173B16C24250
2x413,1278B16C02400
3G413,7278B16C03400
4G414,9394B16C04400
5G416,4464B16C05400
2x614,6362B16C02600
3G615,2362B16C02600
4G616,6510B16C04600
5G618,3605 B16C05600
2x1016,502B16C021000
3G1017,8607B16C031000
4G1019,6748B16C041000
5G1021,4878B16C051000
2x1619,7725B16C021600
3G1620,8869B16C031600
4G1622,71062B16C041600
2x2523,21010B16C022500
3G2524,51227B16C032500
4G2527,11522B16C042500
3x35+1x/G2531,41780B16C043500
3x50+1x/G2534,62410B16C045000

Berica Cavi Spa reserves the right to edit all the information on the website without providing prior notice to customers and / or users