PDF

 

SIAF 5/10 kV EN 50143 (TIPO B)

Cables for signs and luminous-discharge-tube installations operating from a no-load rated output voltage exceeding 1 kV but not exceeding 10 kV, flame retardant, halogen free.

 

  1. Conductor
  2. Insulation

 

APPLICATION: Cables for signs and luminous-discharge-tube installations operating from a no-load rated output voltage exceeding 1000 V but not exceeding 10000 V.

INSTALLATION: For fixed installation within electric and electronic equipment.

 

FEATURES DESCRIPTION STANDARDS
Conductors: annealed tinned copper cl.5 CEI EN 60228 (Tab. 9)
Insulation: silicone rubber EI2  
Insulation colour: on request  
DC resistance: ≤ 20,0 Ω/km CEI EN 60228 (Tab. 9)
Flame retardant:   CEI EN 60332-1-2
Halogen free: (< 0.5 mg/g - 0.5%) CEI EN 50267-2-1/2 IEC 60754-1/2
Rated voltage Uo/U: 5/10 kV  
Testing voltage: 15 kV x 5'  
Max working temperature: 180 °C  
Short-circuit temperature: 350 °C  
Min. installation temperature: -40 °C  
Bending radius: Ø x 4  
Printing: BERICA CAVI SPA ITALY EN 50143 B 5/10kV  

 

TYPE
N° x mm2
MEDIUM Ø OUTER
mm
MEDIUM WEIGHT
kg/km
PRODUCT CODE
1x1 6,3 57 B4301100

 

Berica Cavi S.p.A. reserves the right to change all information on the website without giving prior notice to customers and / or users