EUROSAFE SCREENED 300/500 V (FE180) (PH120)
Power, signal and command cables, Al/Pet tape screen, fire resistant, fire retardant, halogen free.
|
 |
- Conductor
- Insulation
- Assembling
- Drain wire
- Screen
- Sheath
|
|
APPLICATION: Suitable for the transport of energy and the transmission of signals and controls for electrical equipment when you need maximum security against fire, such as emergency lighting and alarm systems, automatic fire detection, fire extinguishing equipment, automatic opening doors, ventilation systems and conditioning, emergency telephone systems.
INSTALLATION: For fixed indoor installation in dry or wet environments and temporarily outdoor. They can be installed on platforms, pipes, conduits and similar systems.
|
| FEATURES |
DESCRIPTION |
STANDARDS |
| Conductors: |
annealed red copper cl.1 |
CEI EN 60228 (Tab. 9) |
| Insulation: |
ceramifiable silicone rubber |
|
| Cores colour: |
|
CEI UNEL 00722 - HD 308 |
| Assembling: |
Pet tape |
|
| Drain wire: |
annealed tinned copper |
|
| Screen: |
Al/Pet tape thickness 9/23 µm covering >110% |
|
| Sheath: |
LSZH compound, M1 quality |
CEI EN 50363 |
| Sheath colour: |
red RAL 3000 |
|
| Fire retardant: |
|
CEI EN 60332-3-24 |
| Flame retardant: |
|
CEI EN 60332-1-2 |
| Halogen free: |
(< 0,5 mg/g - 0,5%) |
CEI EN 50267-2-1/2 - IEC 60754-1/2 |
| Low smoke emission: |
(trasmittance > 60%) |
CEI EN 61034-2 |
| Fire resistant: |
duration 120 min. at temperature of 830 °C (- 0 ÷ + 40 °C) |
CEI EN 50200 |
| Fire resistant: |
cat. C (3h a 950 °C) |
BS 6387 cat. CWZ |
| Fire resistant: |
duration 180 min. at temperature of 750 °C (FE180) |
IEC 60331-21 VDE 472-814 |
| DC resistance: |
according to |
CEI EN 60228 (Tab. 9) |
| Rated voltage Uo/U: |
300/500 V |
|
| Max voltage: |
550 V |
|
| Testing voltage: |
2 kV |
|
| Max working temperature: |
90 °C |
|
| Max conductor temperature: |
180 °C |
|
| Short-circuit temperature: |
350 °C |
|
| Min. installation temperature: |
0 °C |
|
| Bending radius: |
Ø x 8 |
|
| Printing: |
EUROSAFE FE 180 Type SC REENED300/500 V BS 6387 CWZ CEI EN 50200 PH(120) IEC 60332-3-24 CE Year/Lot |
|
|
TIPO N° x mm2 | Ø ESTERNO MEDIO mm | PESO MEDIO kg/km | CODICE |
| 2x0,50 |
5,6 |
36 |
B7302080S |
| 2X0,75 |
6,1 |
49 |
B7302075S |
| 3x0,75 |
6,7 |
65 |
B7303075S |
| 4x0,75 |
7,2 |
79 |
B7304075S |
| 2x1 |
6,7 |
58 |
B7302100S |
| 3x1 |
7,1 |
74 |
B7303100S |
| 4x1 |
7,7 |
91 |
B7304100S |
| 2x1,5 |
8,1 |
82 |
B7302150S |
| 3x1,5 |
8,6 |
107 |
B7303150S |
| 4x1,5 |
9,4 |
133 |
B7304150S |
| 2x2,5 |
8,9 |
107 |
B7302250S |
| 3x2,5 |
9,5 |
142 |
B7303250S |
| 4x2,5 |
10,3 |
179 |
B7304250S |
|
Berica Cavi Spa reserves the right to edit all the information on the website without providing prior notice to customers and / or users