PDF

Cu/LSZH/ISCR/OSCR/LSZH/SWA/LSZH - 0,6/1kV
FG16XHOHM16FM16 - 0,6/1kV

Power, control and signaling cables, with steel braid armour, fire retardant and halogens free

Cu/LSZH/ISCR/OSCR/LSZH/SWA/LSZH - 450/750V

Cca-s1b,d1,a1

APPLICATION: Suitable for transmission of signals and controls in the connections between electrical equipments and data/control center. Typical applications are located in chemical and petrochemical fields, in water treatment and mining.

INSTALLATION: For fixed indoor and outdoor installation even in wet environments. They can be installed on wall and metal structures, on platforms, pipes, conduits and similar systems. Cable for direct and indirect burial.



FEATURES DESCRIPTION STANDARDS
Conductors: annealed red copper cl.5 CEI EN 60228 (Tab. 9)
Insulation: LSZH compound CEI EN 50363
Cores colour: Blue-Black numbered (>1x2x) -Blue-Brown-Black numbered(>1x3x)
Pair/Triad screen: Al/Pet tape
Pair/Triad drain wire: annealed tinned copper 7x0,30mm
Total screen: Al/Pet tape
Total drain wire: annealed tinned copper 7x0,30mm
Inner sheath: LSZH compound CEI EN 50363
Inner sheath colour: Natural or Black RAL 9005 CEI 20-11
Armour: Steel wire with steel tape
Outer sheath: LSZH compound CEI EN 50363
Outer sheath colour: Black RAL 9005 or on request Gray RAL 7001 or Green RAL 6018 CEI EN 50363
Halogens free: (< 0,5 mg/g - 0,5%) CEI EN 50267-2-1/2 - IEC 60754-1/2
Low toxic gases emission: (toxicity index < 2%) CEI 20-37/4-0
Rated voltage Uo/U: 0,6/1 kV CEI 20-11
Max. voltage: 1,2 kV
Testing voltage: 4 kV
Max working temperature: 90 °C
Short-circuit temperature: 250 ° C
Min. installation temperature: 0 °C
Bending radius: Ø x 14
Max standard twisting (2x cable): ≥ 10 spire/metro
REGULATION (UE) 305/2011
AVCP System : 1+ EN 50575:2014 + A1:2016
Classification : Cca-s1b,d1,a1 UNI EN 13501-6
Cca : Heat release and flame spread(FS ≤ 2m) EN 50399
s1b : Smoke transmittance ≥ 60% <80% (TSP ≤ 50 m2 and SPR ≤ 0.25 m2 / s) EN 50399 + EN 61034-2
d1 : No flaming droplets/particles persisting longer than 10 s EN 50399
a1 : Gas acidity (Conductivity <2.5 ms / mm and pH> 4.3) EN 50267-2-3
Flame propagation (H ≤ 425 mm) EN 60332-1-2
Printing: BERICA CAVI S.P.A. ITALY Cu/LSZH/ISCR/OSCR/LSZH/SWA/LSZH 0,6/1 kV Cca-s1b,d1,a1 CE Type- Year/Lot - 00000 m
TYPE

N° x mm2
MEDIUM Ø OUTER
mm
MEDIUM WEIGHT
kg/km
PRODUCT CODE
2x2x0,75 16,9 468 B98C02C075SWA
3x2x0,75 17,9 527 B98C03C075SWA
4x2x0,75 19,2 598 B98C04C075SWA
6x2x0,75 20,7 690 B98C06C075SWA
8x2x0,75 21,9 777 B98C8C075SWA
12x2x0,75 25,6 1032 B98C12C075SWA
16x2x0,75 29,1 1265 B98C16C075SWA
24x2x0,7532,81592B98C24C075SWA
2x2x117,7511B98C02C100SWA
3x2x118,7566B98C03C100SWA
4x2x120,1657B98C04C100SWA
6x2x121,7762B98C06C100SWA
8x2x123,3875B98C08C100SWA
12x2x127,01129B98C12C100SWA
16x2x130,81423B98C16C100SWA
24x2x135,11810B98C24C100SWA
2x2x1,518,8574B98C02C150SWA
3x2x1,520,0654B98C03C150SWA
4x2x1,521,5743B98C04C150SWA
6x2x1,523,5884B98C06C150SWA
8x2x1,525,01010B98C08C150SWA
12x2x1,529,41344B98C12C150SWA
16x2x1,533,71689B98C16C150SWA
24x2x1,538,32137B98C24C150SWA
2x2x2,520,3670B98C02C250SWA
3x2x2,521,7769B98C02C250SWA
4x2x2,523,6904B98C04C250SWA
6x2x2,525,61068B98C06C250SWA
8x2x2,527,31263B98C08C250SWA
12x2x2,532,71686B98C12C250SWA
16x2x2,537,52110B98C16C250SWA
24x2x2,542,5 2715B98C24C250SWA
2x3x0,7518,2552B98C02T075SWA
3x3x0,7519,4630B98C03T075SWA
4x3x0,7520,4700B98C04T075SWA
6x3x0,7523,4880B98C06T075SWA
12x3x0,7528,61297B98C12T075SWA
2x3x119,0599B98C02T100SWA
3x3x120,4697B98C03T100SWA
4x3x121,4769B98C04T100SWA
6x3x124,91021B98C06T100SWA
12x3x130,21465B98C12T100SWA
2x3x1,520,3675B98C02T150SWA
3x3x1,521,8789B98C03T150SWA
4x3x1,523,2900B98C04T150SWA
6x3x1,526,81151B98C06T150SWA
12x3x1,533,11739B98C12T150SWA
2x3x2,522,2818B98C02T250SWA
3x3x2,523,9967B98C03T250SWA
4x3x2,525,31093B98C04T250SWA
6x3x2,529,81461B98C06T250SWA
12x3x2,536,62201B98C12T250SWA

Berica Cavi Spa reserves the right to edit all the information on the website without providing prior notice to customers and / or users