FG4OHG4
Thermocouple cable with twisted cores, silicone rubber insulated and Al/Pet screen
|
 |
- Conductor
- Insulation
- Drain wire
- Screen
- Sheath
|
|
APPLICATION: Extension and compensating cables for thermocouples.
INSTALLATION: For fixed and mobile installation in dry or wet environments at high temperature, subjected to low intensity mechanical stresses however in the absence of tensile stresses and forced displacements, laying in catenary with repeated cycles is not allowed. The Al / PET screens the cable from electrostatic interference.
|
| FEATURES |
DESCRIPTION |
STANDARDS |
| Conductors: |
type T : +Cu -CuNi type J : +Fe -CuNi type E : +NiCr -CuNi type K : +NiCr -NiAl type W : +Fe -CuNi type S and R : +Cu -CuNi type B : +Cu -Cu |
|
| Insulation: |
silicone rubber |
|
| Cores colour: |
see thermocouple table |
|
| Screen: |
Al/Pet tape |
|
| Drain wire: |
annealed red copper, diameter 0,5mm |
|
| Sheath: |
silicone rubber |
|
| Sheath colour: |
see thermocouple table |
|
| Flame retardant: |
|
CEI EN 60332-1-2 |
| Radiation resistant: |
2x107 kJ/kg |
|
| Halogen free: |
(< 0,5 mg/g - 0,5%) |
CEI EN 50267-2-1/2 - IEC 60754-1/2 |
| Working temperatures: |
-60 °C ÷ +180 °C |
|
| Bending radius: |
Ø x 7,5 |
|
|
|
TYPE N° x mm2 |
MEDIUM Ø OUTER mm |
MEDIUM WEIGHT kg/km |
PRODUCT CODE |
| 2x0,5 |
5,8 |
60 |
B4702050(*)SA |
| 2x0,8 |
6,8 |
64 |
B4702080(*)SA |
| 2x1 |
7,0 |
71 |
B4702100(*)SA |
| 2x1,3 |
7,8 |
82 |
B4702130(*)SA |
| 2x1,5 |
8,3 |
92 |
B4702150(*)SA |
|
(*) Add J for J-W-T-S calibration, K for K calibration
Berica Cavi S.p.A. reserves the right to change all information on the website without giving prior notice to customers and / or users