FR2DRA
Thermocouple cable with PVC insulation, armoured with galvanized steel braid
|
 |
- Conductor
- Insulation
- Sheath
- Armour
|
|
APPLICATION: Extension and compensating cables for thermocouples.
INSTALLATION: For fixed and mobile installation in dry environments. Thanks to the braid of galvanized steel also supports mechanical stress condition, laying in catenary with repeated cycles is not allowed.
|
| FEATURES |
DESCRIPTION |
STANDARDS |
| Conductors: |
type T : +Cu -CuNi type J : +Fe -CuNi type E : +NiCr -CuNi type K : +NiCr -NiAl type W : +Fe -CuNi type S and R : +Cu -CuNi type B : +Cu -Cu |
|
| Insulation: |
PVC |
|
| Cores colour: |
see thermocouple table |
|
| Sheath: |
PVC ,oval shape |
|
| Sheath colour: |
see thermocouple table |
|
| Armour: |
braid of galvanized steel |
|
| Flame retardant: |
|
CEI EN 60332-1-2 |
| Radiation resistant: |
8x107 kJ/kg |
|
| Working temperatures: |
-25 °C ÷ +105 °C |
|
| Bending radius: |
Ø x 7,5 |
|
|
|
TYPE N° x mm2 |
MEDIUM Ø OUTER mm |
MEDIUM WEIGHT kg/km |
PRODUCT CODE |
| 2x0,5 |
5,8x4,1 |
39 |
B4602050(*)AR |
| 2x0,8 |
6,8x4,6 |
53 |
B4602080(*)AR |
| 2x1 |
7,2x4,7 |
64 |
B4602100(*)AR |
| 2x1,3 |
7,8x5,1 |
78 |
B4602130(*)AR |
| 2x1,5 |
8,0x5,3 |
89 |
B4602150(*)AR |
|
(*) Add J for J-W-T-S calibration, K for K calibration
Berica Cavi Spa reserves the right to edit all the information on the website without providing prior notice to customers and / or users